AO11   AO12   AO13   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv12.0   SASv12.0_Installation   SASv13.0   SASv13.0_Installation   SASv13.5   SASv13.5_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   XSA_old   esas   incoming  

Logged in as guest

Viewing EPICMOS/4535
Full headers

From: th@astro.noa.gr
Subject: quantum efficiency
Compose reply
Move To:
2 replies: 1 2
1 followups: 1

Private message: yes  no

Notes:

Notification:


Date: Thu, 24 Jan 2002 13:49:26 GMT
From: th@astro.noa.gr
To: xmmhelp@xvsoc01.vilspa.esa.es
CC: th@astro.noa.gr
Subject: quantum efficiency
Full_Name: Athanassios Akylas
Submission from: (NULL) (195.251.202.44)


Dear , 
I would like to know whether or not I can see the quantum efficiency for data 
with pattern grater that 1 . If not then does sas use the information  for
patterns 
grater than 1 in order to perform some spesific tasks such as arfgen or
eexpmap.
I have the impression that at least for the second case the exposure map should

be different according to the specified patterns range..
Best regards 

Reply 1

Resend
From: Matteo Guainazzi <xmmhelp@xmm.vilspa.esa.es>
To: th@astro.noa.gr
Subject: Re: quantum efficiency (PR#4535)
Date: Thu Jan 24 18:11:27 2002
Dear Athanassios,

 you can see the quantum efficiency for, e.g., PATTERN=6, using
"calview":

 "View" --> "QuantumEfficiency" --> "6"

 Regards,

 Matteo Guainazzi


Followup 1

Compose reply
Date: Fri, 25 Jan 2002 11:07:22 +0200 (EET)
From: "A. Akylas" <th@astro.noa.gr>
To: Matteo Guainazzi <xmmhelp@xvsoc01.vilspa.esa.es>
Subject: Re: quantum efficiency (PR#4535)
Dear Mateo 

This is true only for MOS instrument if you try EPN
then produces the following error The error code was: illegal Patternld
Illegal pattern ID 3 in selecting quantum efficiency curve -legal range is 
 0-1 

Could you  please tell if this is normal and furthermore if in PN analysis 
the QE for patterns 2,3... are taken under consideration?

Best regards 

Thanassis Akylas


----------------------------------------------------------------
    Mr. A. Akylas                      th@astro.noa.gr
Institute of Astronomy & Astrophysics  phone: ++30-1-6132066  
  National Observatory of Athens       fax:   ++30-1-8040453
I. Metaxa & B. Pavlou, Palaia Penteli  
   Athens, GR-15236, GREECE 
----------------------------------------------------------------


On Thu, 24 Jan 2002, Matteo Guainazzi wrote:

> Dear Athanassios,
> 
>  you can see the quantum efficiency for, e.g., PATTERN=6, using
> "calview":
> 
>  "View" --> "QuantumEfficiency" --> "6"
> 
>  Regards,
> 
>  Matteo Guainazzi
> 



Reply 2

Resend
From: Matteo Guainazzi <xmmhelp@xmm.vilspa.esa.es>
To: th@astro.noa.gr
Subject: Re: quantum efficiency (PR#4535)
Date: Fri Jan 25 23:32:11 2002
Dear Thanassis,

 the QE CCF pn costituents indeed contain information on the
quantum efficiency only for singles and doubles events. "calview"
errouneusly shows the whole range of PATTERNS (0-31) if the pn
instrument is selected.

 The response matrix generators in SASv5.2 deal only with pn
single events. Matrices with any combinations of patterns will
be able to be generated only starting from SASv5.3.

 Regards, Matteo

Up to top level
AO11   AO12   AO13   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv12.0   SASv12.0_Installation   SASv13.0   SASv13.0_Installation   SASv13.5   SASv13.5_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   XSA_old   esas   incoming  